EIM

Infotrol-EIM.
Energy Intensity Management

EIM monitors energy intensity across production lots, identifies abnormal operation, explains the variables driving the increase, and guides engineers toward what to check first.

Equipment & Process Energy Intensity Monitoring and AI Diagnostics for Process Industries

EIM Issues screen: a high-intensity lot with its causes, evidence tags and recommended checks

The problem

Energy consumption is visible.
Efficiency loss is not.

Plants already meter how much energy they use. What stays hidden is whether a given run was efficient for what it produced — and if not, why.

01

Consumption alone says nothing about efficiency

Totals rise and fall with output. Without a per-unit figure compared against like-for-like conditions, a run that wasted energy looks much the same as a normal one.

02

Checking it by hand takes too long

Matching production records against measurement data run by run is slow work, so by the time a pattern is noticed the run is long finished.

03

The diagnosis lives in people's heads

Which cause to suspect and what to inspect depends on who is on shift. That know-how is rarely written down, and it leaves when they do.

How EIM works

From a high reading to the item you should check first.

Four stages run as one diagnosis. Each stage hands its result to the next, automatically, every time a new production record arrives.

01 Monitor & detect

Identify high-intensity lots

Which runs used more energy than they should have?

Energy intensity per lot, or per equipment and process
Compared with the normal range for the same product and conditions
Runs outside that range are flagged
→

02 Explain

Understand what influenced it

Which process variables moved the number, and by how much?

The measured rise is split into the part explained by operating conditions and the part that is not
The condition-driven part goes to variable contribution analysis and cause inference
→

03 Diagnose

Connect conditions to causes

What could produce this combination of readings?

Engineer knowledge held as process, variable, cause and action
Measured tag states matched against the rules
Rules that are met produce cause candidates
→

04 Guide action

Know what to check first

Where should the engineer start, and why?

Evidence tags and their values for each candidate
Equipment and tags to inspect, with the action to take
Ordered by how much each variable contributed

Product

The diagnosis, as your team sees it.

These are the screens an engineer works from.

Issues

One issue. The data, causes and checks in one view.

Open a flagged lot and everything needed to act on it is on the same screen — where it sits against its peers, what the rules point to, and what to inspect.

1
High-intensity lots for the period, with how far each exceeded its peers
2
Causes that met their rules, each with the evidence tags behind them
3
Checks and follow-up actions, plus the AI variable contributions (XAI)
EIM Issues screen with issue lot list, assessment, causes of the rise and recommended checks
EIM Summary screen with recent lot KPIs, intensity distribution and recent issues

Summary

See energy intensity across your production.

The daily view: how the latest lot performed, how that compares with the best run of the same product, and what needs attention.

1
Intensity, cycle time, production weight and energy use, each against its best value
2
Where this lot falls in the distribution for its product
3
Recent issues, each linking straight through to its diagnosis

Lot Explorer

Compare lots under similar conditions.

Pick a product and look across its lots. Every variable is placed against the normal band for that product, so what was different about one run stands out.

1
Lots of the same product, with intensity and cycle time side by side
2
A lot profile showing each variable against the product's normal range
3
Gap against the median and against the best lot, variable by variable
EIM Lot Explorer with a lot profile showing each variable against the product's normal range
EIM Equipment and Tags screen with out-of-range tag ranking and per-lot tag trends

Equipment & Tags

Track the process variables that need attention.

Tags that keep leaving their normal range are ranked, and their trend across lots shows when the drift started.

1
Tags ranked by how often they fall outside their reference range
2
Lot-by-lot trend for a selected tag, with out-of-range lots marked
3
How that tag relates to energy intensity for the product

Explainable AI

See what drives energy intensity.

EIM explains the difference between a target lot and a normal reference lot by showing how much each process variable contributed to the AI-predicted energy intensity — in which direction, and by how much.

Waterfall diagram breaking the difference between a reference lot and a target lot into per-variable contributions

What the engineer gets

The predicted intensity for this lot next to a normal lot of the same product
Each variable's contribution, separated into those that raised it and those that lowered it
A check order, largest contribution first

How it is computed

Shapley values distribute the predicted difference across variables, so the parts add up to the whole
Calculated for each individual lot, not as a general model trend
The reference lot is the lot of the same product, assessed as normal, with the closest charge weight

How to read it: a contribution is how much a variable moved the model's prediction. It shows where to look first, not which physical fault occurred.

Site knowledge

Turn field experience into structured diagnosis.

EIM structures your engineers' knowledge into relationships between process variables, conditions, causes and actions. When measured conditions satisfy a rule, EIM presents the matching cause candidate and the checks that go with it.

Variable

Vacuum low, process time high

→
Condition

Both conditions met together

→
Cause candidate

Leak suspected

→
Action

Check the vacuum line

Built from your engineers, kept after they move on

Rules are written from interviews about what they check when intensity rises
Evidence tags, the rules applied and the knowledge base version are stored with each diagnosis
Candidates stay candidates — the engineer confirms the cause on site and that result feeds back into the rules
Ontology knowledge base authored in Protege, linking processes, variables, causes and actions

Case study · Heat treatment

From energy diagnosis to process improvement.

A heat treatment line, managed per lot, with lots compared against normal runs of the same product using MES lot history and equipment measurement data.

Diagnosis

Ramp-up time identified

EIM analysis pointed to ramp-up time as the main influence on rising energy intensity in the line.

→

Improvement

Equipment and control

To shorten ramp-up, furnace equipment was replaced and Infotrol-MPC was applied to the heating control.

→

Result

Shorter, steadier heating

Average ramp-up time came down, operation became more stable and electricity use fell with it.

Confirmed

6.5 min

shorter average ramp-up time

~8%

reduction against the previous average

Heat treatment case: system configuration and MPC-controlled heating trend

EIM was used for the diagnosis. The ramp-up time reduction was achieved together with the equipment replacement and Infotrol-MPC that followed, and is not presented as an energy saving delivered by EIM on its own.

EIM Assistant

Ask EIM. Get answers from your diagnosis data.

The Assistant interprets a question in plain language, retrieves the relevant diagnosis data through read-only tools, and answers from what it retrieved — so nobody has to learn the screens or the analysis procedure first.

“Which lots had high energy intensity this month?”
“Which variables contributed most to the increase?”
“What cause candidates and checks were identified?”
EIM Assistant answering a question about high-intensity lots with the retrieved evidence shown

What it can do today

Looks up lot-level diagnosis results: lot information, assessment, cause candidates and AI contribution variables
Answers from what the tools returned, with the retrieved evidence shown alongside
Records every question, tool call and answer

What it does not do

No direct database access, no writing, no equipment control — the session is read-only
An answer whose figures do not match the retrieved values is not shown
No general document search, work order creation, operating changes or optimization runs

System & deployment

Runs on your server, on the data you already have.

Everything from energy intensity calculation to cause inference runs on an on-site server alongside the existing MES and measurement systems. Diagnosis data stays on site and users reach it through a browser.

EIM system architecture: site systems, data storage, on-site analysis engine and web service

Data requirements

What EIM needs from your existing systems

Data for energy intensity

MES lot information: lot ID and part number
Process start and end time for each lot
Production output or charge weight
Energy use measurement at a resolution that covers the lot window

Data for cause diagnosis

Temperature, current, vacuum and other process variables
Measurement tags, typically over OPC
Engineers' inspection experience and the actions they take

Deployment

How a rollout runs

01

Data connection

MES, tags and calculation rules are connected and the data is checked for quality.

02

Field interviews

Engineers are interviewed and their checks become the first set of knowledge base rules.

03

Model training

Models are trained and validated repeatedly, and the results are reviewed before release.

04

On-site installation

The server is installed and scheduled diagnosis runs are registered.

Ready to optimize your operations?

Review your existing MES and sensor data to identify what EIM can monitor and diagnose in your process. We agree a pilot scope from what the review finds.

Request a Data Assessment →
Infotrol Technology Co., Ltd
15F CBS Bldg., 159-1, Mokdongseo-ro Yangcheon-gu,
Seoul, Korea 07997
COMPANY
E : infotrol.web@infotrol.co.kr
T : 82-2-2061-7291
F : 82-2-2061-7290
CEO
E : weonhokim@infotroltech.com
MT: 82-10-2320-4031